Ifm  |  SKU: IF-PI2897-E  |  Barcode: DOES NOT APPLY

Ifm PI2897 Flush Pressure Sensor With Display

$894.44 USD
Shipping calculated at checkout.

Ifm PI2897 Flush Pressure Sensor With Display is backordered and will ship as soon as it is back in stock.


As a Canadian company, please note that any product made in China and imported into the United States will be subject to a 30% tariff, which must be paid separately upon delivery. Please refer to our Shipping Policy for full details.

🚚 We Ship Worldwide! Get your order delivered anywhere.

Delivery And Shipping

Both Standard and Express shipping options are available at checkout.

Tariffs And Fees

Items made in China and imported in the United States will be hit with a 50% fee upon arrival. Extra Fees Might Apply.

Items made in Canada and imported in the United States will be hit with a 35% fee upon arrival. Extra Fees Might Apply.

Items lacking a specified Country of Origin will be classified as originating from China by customs, resulting in a 30% import tax upon delivery in the U.S. Extra Fees Might Apply.

Subscribe to our newsletter

Sign up for exclusive offers.

Industrial Automation Parts is only an authorized distributor for DeLock and is not authorized for any other manufacturers. Manufacturer's warranty and support do not apply. Our IAP warranty of three months is applicable.

Country Of Origin:

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
-0.05...1 bar -50...1000 mbar -0.73...14.5 psi -5...100 kPa
Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Application
System gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25...125; (145 max. 1h)
Min. bursting pressure
30000 mbar 435 psi 3000 kPa
Pressure rating
10000 mbar 145 psi 1000 kPa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure
MAWP (for applications according to CRN) [bar] 10
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Measuring principle hydrostatic
Integrated watchdog yes
2-wire
Operating voltage [V] 20...32 DC
Current consumption [mA] 3.6...21
Power-on delay time [s] 1
3-wire
Operating voltage [V] 18...32 DC
Current consumption [mA] < 45
Power-on delay time [s] 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Number of analog outputs 1
Analog current output [mA] 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub - 10 V) / 20 mA
Measuring/setting range
Measuring range
-0.05...1 bar -50...1000 mbar -0.73...14.5 psi -5...100 kPa
Set point SP
-48...1000 mbar -0.7...14.5 psi -4.8...100 kPa
Reset point rP
-50...998 mbar -0.73...14.47 psi -0.5...99.8 kPa
Analog start point
-50...750 mbar -0.73...10.88 psi -5...75 kPa
Analog end point
200...1000 mbar 2.9...14.5 psi 20...100 kPa
In steps of
1 mbar 0.01 psi 0.1 kPa
Factory setting
SP1 = 250 mbar rP1 = 230 mbar
SP2 = 750 mbar rP2 = 730 mbar
ASP = 0 mbar AEP = 1000 mbar
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,2; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,05; (0...70 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,15; (0...70 °C)
Reaction times