APC AC ACF400 Rack Air Removal Unit SX 100-240V 50 60HZ f NetShelter 600mm RTL
APC AC ACF400 Rack Air Removal Unit SX 100-240V 50 60HZ f NetShelter 600mm RTL is backordered and will ship as soon as it is back in stock.
🚚 We Ship Worldwide! Get your order delivered anywhere.
Delivery And Shipping
Delivery And Shipping
Both Standard and Express shipping options are available at checkout.
Tariffs And Fees
Tariffs And Fees
Being a Canadian company, our U.S. shipments are subject to tariffs. Under DDP (Delivered Duty Paid), all applicable tariffs and fees are calculated and paid upfront at checkout.
Industrial Automation Parts is only an authorized distributor for DeLock and is not authorized for any other manufacturers. Manufacturer's warranty and support do not apply. Our IAP warranty of three months is applicable.
Country Of Origin: China
Nominal Input Voltage
100V, 120V, 200V, 208V, 230V
Input Connections
IEC-320 C14, NEMA 5-15P
Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 600mm enclosures.
High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data center. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. With a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control. This space-saving solution mounts to the back of either the NetShelter SX or VX enclosure, requiring zero U space.
Includes: Documentation CD, Installation Guide, Operations and Maintenance Manual
Adjustable mounting frame
The frame can mount on Netshelter SX or VX enclosures and extends to accommodate 42U, 47U or 48U rack heights.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Ducted Exhaust System
Removes hot air from the data center to prevent re-circulation and eliminate air mixing.
Fan guards
A safety measure that provides protection from the fan opening by covering the inlet.
Fault-tolerant fan system
In the event of a fan failure, the remaining fan(s) will continue to operate.
Field replaceable components
Fans and electronics module can be readily replaced without uninstalling the unit.
-