Country Of Origin:
Measuring range |
|
||||
---|---|---|---|---|---|
Process connection | Clamp 2" DIN 32676 series C |
System | gold-plated contacts | ||
---|---|---|---|
Media | ultra-pure water; water; water-based media | ||
Note on media |
|
||
Medium temperature [°C] | -20...100 | ||
Min. bursting pressure |
|
||
Pressure rating |
|
||
Vacuum resistance [mbar] | -1000 |
Operating voltage [V] | 18...32 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 75 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 5 |
Measuring principle | ultrasonic |
Total number of inputs and outputs | 2 |
---|
Inputs |
|
---|
Total number of outputs | 2 | ||||
---|---|---|---|---|---|
Output signal |
|
||||
Electrical design | PNP/NPN | ||||
Short-circuit protection | yes | ||||
Type of short-circuit protection | yes (non-latching) | ||||
Overload protection | yes |
Number of analog outputs | 1 |
---|---|
Analog current output [mA] | 4...20 |
Max. load [Ω] | 500 |
Number of digital outputs | 2 |
---|---|
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | 0...10000 |
Measuring range |
|
||||
---|---|---|---|---|---|
Display range |
|
||||
Resolution |
|
||||
Set point SP |
|
||||
Reset point rP |
|
||||
Analog start point ASP |
|
||||
Analog end point AEP |
|
||||
Low flow cut-off LFC |
|
||||
Frequency end point, FEP |
|
||||
Frequency at the end point FRP [Hz] | 1...10000 |
Pulse length [s] | 0.002...2 |
---|---|
Pulse value | 0.02...99990000 I |
Measuring range [°C] | -20...100 |
---|---|
Display range [°C] | -44...124 |
Resolution [°C] | 0.1 |
Set point SP [°C] | -19.6...100 |
Reset point rP [°C] | -20...99.6 |
Analog start point [°C] | -20...76 |
Analog end point [°C] | 4...100 |