Ifm SM6020 Magnetic-Inductive Flow Meter
Ifm SM6020 Magnetic-Inductive Flow Meter is backordered and will ship as soon as it is back in stock.
As a Canadian company, please note that any product made in China and imported into the United States will be subject to a 30% tariff, which must be paid separately upon delivery. Please refer to our Shipping Policy for full details.
🚚 We Ship Worldwide! Get your order delivered anywhere.
Delivery And Shipping
Delivery And Shipping
Both Standard and Express shipping options are available at checkout.
Tariffs And Fees
Tariffs And Fees
Items made in China and imported in the United States will be hit with a 30% fee upon arrival. Extra Fees Might Apply.
Items made in Canada and imported in the United States will be hit with a 35% fee upon arrival. Extra Fees Might Apply.
Items lacking a specified Country of Origin will be classified as originating from China by customs, resulting in a 30% import tax upon delivery in the U.S. Extra Fees Might Apply.
Subscribe to our newsletter
Sign up for exclusive offers.
Industrial Automation Parts is only an authorized distributor for DeLock and is not authorized for any other manufacturers. Manufacturer's warranty and support do not apply. Our IAP warranty of three months is applicable.
Country Of Origin:
Product Overview
Inputs/Outputs:
- Digital Outputs: 2
- Analog Outputs: 1
- Input: Counter reset
- Output Signals: Configurable (switching, analog, pulse, IO-Link, frequency)
Measuring Range:
- Flow Rate: 0.05–35 l/min, 0.003–2.1 m³/h, 0.6–555 gph, 0.01–9.25 gpm
- Display Range: -42–42 l/min, -2.5–2.5 m³/h, -666–666 gph, -11.1–11.1 gpm
Process Connection:
- G 1/2 DN15 flat seal
Media:
- Conductive liquids, water, water-based media (conductivity ≥ 20 µS/cm, viscosity < 70 mm²/s)
Temperature/Pressure:
- Medium Temp: -20...90°C
- Pressure Rating: 16 bar / 1.6 MPa
Electrical Data:
- Voltage: 18–30 V DC
- Current Consumption: < 80 mA
- Protection Class: III
- Reverse Polarity Protection: Yes
Output Specifications:
- Max. Voltage Drop: 2 V DC
- Max. Current: 100 mA
- Analog Output: 4–20 mA (scalable)
- Pulse Output: Flow rate meter
Measuring/Setting Ranges:
- Set Point: 0.25–35 l/min
- Low Flow Cut-off: 0.05–1.75 l/min
- Frequency Range: 1–10,000 Hz
Temperature Monitoring:
- Measuring Range: -20–90°C
- Accuracy: ± 2.5 K
Accuracy:
- Flow: ± (0.8% MW + 0.2% MEW)
- Repeatability: ± 0.2% MEW